Logo leading to homepage
One survey, unlocking a world of deliverables

As Built P&ID Drawings for Process Sites

Neonex Digital produces P&ID drawings that match your plant as it stands today. We survey the site with a laser scanner and a manual walkdown, draw every line, valve and instrument as a smart P&ID in Autodesk Plant 3D, and check each sheet three times before it reaches you. We work on tank storage terminals, chemical plants, water treatment and biogas sites across the UK and Europe.

01 · The basics

What is an as built P&ID?

An as built P&ID is a piping and instrumentation diagram that shows the plant exactly as it is installed, not as it was designed. It records every line, valve, instrument and piece of equipment, with tags and line numbers that match the labels on site.

A design P&ID shows what the engineers intended to build. An as built P&ID shows what the contractor actually installed, including the changes made on site: rerouted lines, extra vents and drains, swapped valve types, spec breaks in different places and instruments added after commissioning. Once it is checked against the plant, the sheet is issued at an as built revision, and every later change is drawn onto it under management of change.

Your P&ID drawings are the reference for maintenance, isolations, inspections and project work. When they are wrong, every one of those jobs starts from a wrong picture.

What an as built P&ID records

  • Every line, with line numbers that match the site
  • Every valve, with its type and tag
  • Instruments and control loops
  • Equipment, tagged to match the labels on site
  • Changes made on site since the original design
As built P&ID drawing of a road loading bay, drawn as a smart P&ID in Autodesk Plant 3D

3 checks

On every sheet before it is issued

4 days

On site for a small tank terminal

600+

P&IDs drawn for a single chemical terminal

25+ years

In oil and gas, with 15+ in laser scanning

02 · See one

Example point cloud used to draw P&ID drawings

This is a section of a real process site we have scanned, the same kind of data our designers work from when they draw P&ID drawings. Every pipe, valve, flange and instrument is captured to within a few millimetres, so a line that disappears into a rack or runs at height can still be traced from the office.

Registered point cloud of two storage silos with measurements and asset tags

Rotate, zoom and pan to look around. When a question comes up during drafting, such as where a drain sits or which way a valve faces, the designer checks it here instead of sending someone back to site.

03 · The problem

Why do P&IDs stop matching the plant?

Most sites change faster than their drawings. After ten or twenty years, a set can be a mix of original design drawings, scanned paper and AutoCAD files in different styles.

Point cloud and Plant 3D model of a pipe rack area

Small modifications

Changes go in under management of change, but the drawing update never quite follows.

Redlines left in the office

Marked up sheets sit in a site office and never reach CAD.

Contractor tie ins

Tie ins drawn on the contractor's own sheets, or not drawn at all.

A mixed drawing set

Original design drawings, scanned paper and AutoCAD files, each in a different style.

Time for a fresh survey

Once a set has drifted this far, a new survey makes more sense than another round of redlines.

Neonex Digital guided us through our survey requirements and delivered a solution perfectly tailored to our project's needs, we look forward to working with them again.
Client feedback

04 · The process

How do we produce as built P&ID drawings?

We combine a 3D laser scan with a walkdown by surveyors who draw P&IDs for a living. Drafting starts after the first day on site, so drawings and survey run side by side.

  1. 1

    Agree the standard

    We set symbols, line and equipment numbering, title blocks and borders with you, or follow your existing standard.

  2. 2

    Scan and walk the site

    We laser scan the process areas and walk every line with marked up drawings, including remote E&I instrumentation the scanner cannot read.

  3. 3

    Model the pipework

    Process pipework is modelled in Plant 3D from the point cloud, so routes, valves and connections are checked against measured data rather than memory.

  4. 4

    Draw the P&IDs

    Our lead designer drafts each system as a smart P&ID. For tank terminals we add a side elevation sheet per tank, linking roof instrumentation to the inlet and outlet valves.

  5. 5

    Check three times

    The surveyor who walked the area checks first, a second checker who has never seen the drawing checks again, then a final check before issue.

  6. 6

    Handover

    You get the Plant 3D project, DWG and PDF sheets, plus line, valve and instrument lists if you need them.

Scan to model

Point cloud and model, side by side

The registered point cloud on one side, the finished Plant 3D model on the other. Every pipe, valve and vessel in the model is fitted to what the scanner measured.

05 · The outputs

What do you get back?

Our P&ID drawing services deliver every job as smart P&IDs in Autodesk Plant 3D, because the data behind the drawings is what produces your lists and registers.

If your site works in plain AutoCAD, you still get standard DWG and PDF sheets in your border and title block. They are a straight export from the smart P&ID, so there is no redrawing and no extra cost.

Cost

How much do P&ID drawings cost?

£500+

Per P&ID sheet, up to £1,500, all three checks included

Per day

Site survey, priced per site day

4 days

On site for a small terminal

2 to 3 wks

On site for a large one

The cost of P&ID drawings depends on three things: the site survey, any E&I survey, and the drafting. A simple tank sheet sits at the low end, a busy manifold or process unit at the high end. Where remote instrumentation, junction boxes and control loops need recording, an E&I surveyor traces them back from the field. Travel outside London is quoted separately, and redline updates to existing sheets cost less than new drawings.

Ask us for a quote.

06 · Walkdown or scan

Do you need a laser scan, or is a walkdown enough?

It depends on how far your drawings have drifted and what you will use them for next. A walkdown on its own suits small, simple areas. Adding a laser scan costs more on day one but stops the return visit when a line cannot be traced.

1

Traditional walkdown

A surveyor walks every line with the current drawings, tracing pipework by eye. Quickest to start and best for a few systems or a small, open area, but hard going in racks, at height or in congested plant.

2

Walkdown plus laser scan

The same walkdown, backed by a 3D scan. Lines in racks and at height are traced from measured data, anything missed is checked from the office, and you keep the point cloud and a Plant 3D model.

3

Redlines only

Only a few known changes? We can redraw your marked up sheets without a survey.

For full sites, congested plant and upcoming project work, we recommend the walkdown plus scan.

07 · Compliance

Which regulations depend on accurate P&IDs?

Most process safety duties assume your drawings match the plant. These are the ones that lean on them hardest.

  1. 1

    PSSR

    The written scheme of examination relies on knowing every pressure system and its protection (HSE guidance).

  2. 2

    COMAH

    Major hazard sites must show they understand their plant.

  3. 3

    DSEAR

    We supply the drawings that DSEAR studies are built on. We do not carry out the studies.

  4. 4

    HAZOP

    A study is only as good as the drawings it reviews.

  5. 5

    COSHH, MHSWR and permits

    Workplace safety rules and Environment Agency permits all assume your drawings match the plant.

Further reading

Guides to P&IDs

Our P&ID series starts with what a P&ID is and works through each part of the drawing, from borders and equipment to pipelines, instrumentation and standards, then on to smart P&IDs.

What is a P&ID?

What is a P&ID?

P&ID Introduction? If you’ve ever asked, “What is a P&ID?”, you’re not alone. A Piping and Instrumentation Diagram (P&am...
Read the guide
Layout of a P&ID

Layout of a P&ID

The layout of a P&ID plays a vital role in how effectively the diagram communicates process information. While every P&ID captures t...
Read the guide

P&ID standards

P&ID Symbols for identifying asset types/
Field and Remote instrumentation symbols and codes/
Standardising notes as short codes/
Equipment, Pipelines and asset identification codes for asset management/

08 · Your questions

Questions about P&ID drawings

The questions we are asked most often. If yours is not here, get in touch.

Who leads your survey

The work is led by Lewis Boxer, who spent 25 years in oil and gas, including the CAD and document control team that managed the Coryton Refinery P&ID set. Our P&ID designers each have at least ten years of oil and gas experience, and our surveyors hold CCNSG safety passports. P&ID projects Lewis has led include a full P&ID set and asset register for Stolt Haven Dagenham, scan, model and P&IDs for five VARO Energy terminals in Switzerland, as built P&IDs for six UK fuel terminals, and more than 600 P&IDs for a single US chemical terminal.

Yes. We can survey one system or one area and redraw just those sheets in your existing standard, so they match the rest of the set.

We follow your site standard where one exists. Otherwise we draw to ISO 10628 symbols with a clear legend sheet; see our P&ID standards guide.

Yes. Our surveyors work on operating COMAH sites under your permit system, and we have scanned in DSEAR zones 1 and 2 (how we do it). Gas monitors are supplied by site.

Yes. We sign NDAs, and any drawing work shared with our wider team has client names and borders removed until the final issue.

Yes. The pipework model we build to check the P&IDs can be finished as a full Plant 3D process model, with isometrics and orthographic drawings.

Drafting starts after the first day on site, so you see the first drawings while we are still surveying. A small terminal can take 4 days on site, while a large site can take 2 to 3 weeks. We give you a programme with the quote, so you know when each area's drawings will arrive.

Keeping them current

A P&ID set you can keep up to date

Once each sheet is checked against the plant, it is issued at an as built revision, so every later change can be drawn onto it under management of change.

  • Plant 3D project, DWG and PDF sheets in your own standard
  • Line, valve and instrument lists from the same data
  • Redline updates whenever the plant changes

Ready to scope your P&IDs?

Send us the site and your current drawings, and we will come back with questions or a quote.

Talk to us about your P&IDs
Neonex Digital Transparent White Logo
Neonex Digital Ltd.
Registered in England and Wales, company number 16047925.

Registered office: The Mousery, Beeches Road, Battlesbridge, Essex, SS11 8GH.
© 2026 Neonex Digital Ltd. All Rights Reserved. | Privacy Policy

Are your P&IDs
still accurate?

We can help you:

  • ✓ Standardise your P&IDs
  • ✓ Update P&IDs to As-Built Status
  • ✓ Convert P&IDs into a Smart Format
  • ✓ Asset Scrape P&IDs

Book a free 20-minute P&ID consultation